Development of an LC-MS/MS Method for the Assessment of Selected Active Pharmaceuticals and Metabolites in Wastewaters of a Swiss University Hospital
Author(s) -
Silwan Daouk,
Sandrine FleurySouverain,
Youssef Daali
Publication year - 2015
Publication title -
chimia international journal for chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.387
H-Index - 55
eISSN - 2673-2424
pISSN - 0009-4293
DOI - 10.2533/chimia.2015.684
Subject(s) - ultrapure water , chromatography , chemistry , solid phase extraction , detection limit , effluent , extraction (chemistry) , analyte , residue (chemistry) , mass spectrometry , liquid chromatography–mass spectrometry , environmental science , biochemistry , environmental engineering
A multi-residue analytical method was developed and validated for the quantification of 11 selected active pharmaceutical ingredients (API) and 2 human metabolites in hospital effluents using solid-phase extraction followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Targeted analytes belong to different therapeutic classes: non steroidal anti-inflammatory drugs (NSAID), analgesics, antibiotics and psychiatric drugs. Solid-phase extraction recoveries ranged between 21 and 101% for the selected API. Calibration curves were built with 6 standard samples prepared in ultrapure water ranging from 0.05 to 10 ?g/L and showed regression coefficients above 0.994. The instrumental detection limits (IDL) varied between 0.05 and 5 ?g/L, and the method detection limits (MDL) between 0.1 and 100 ng/L. Precision of the method, evaluated with spiked water samples at four different concentrations, varied between 84 and 117% for all compounds and an overall variability below 20%, with the exception of carbamazepine (71–123%). Except for two compounds, recoveries of spiked hospital wastewaters at four different concentrations (0.1, 1, 10 and 100 ?g/L) varied between 44 and 133%, with relative standard deviation (RSD) between 0.6 and 28.5%. The evaluation of the matrix effects showed that diluted samples exhibit lower signal suppression. Analysis of effluent samples from a Swiss university hospital resulted in a mean detection frequency of 92% for the selected compounds, with concentrations up to 1535 ?g/L for the analgesic paracetamol.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom