Penetrating atherosclerotic ulcer of the ascending aorta
Author(s) -
С. Ю. Болдырев,
В. Н. Суслова,
В. А. Пехтерев,
К. О. Барбухатти,
В. А. Порханов
Publication year - 2020
Publication title -
vestnik hirurgii im. i.i. grekova/vestnik hirurgii imeni i.i. grekova
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.136
H-Index - 7
eISSN - 2686-7370
pISSN - 0042-4625
DOI - 10.24884/0042-4625-2020-179-2-44-46
Subject(s) - ascending aorta , medicine , prosthesis , aorta , surgery , aortic valve , cardiology
To date, the incidence of penetrating aortic ulcers is from 2 to 7 % of all cases of acute aortic syndrome, localization of this pathology in the ascending aorta are casuistic. We present the case of an intraoperative finding of a penetrating ulcer of the ascending aorta. The patient underwent separate prosthetics of the ascending aorta with the vascular prosthesis Uni-Graft No. 28 and the aortic valve prosthesis with the mechanical prosthesis Medtronic No. 23. The patient was discharged on the 8th day in a satisfactory condition. Penetrating atherosclerotic ulcer is a potentially life-threatening condition, the detection of which requires aggressive tactics of surgical treatment.