Test procedures for an acid battery for diagnostic purposes
Author(s) -
J. Pszczółkowski,
G. Dyga
Publication year - 2019
Publication title -
autobusy
Language(s) - English
Resource type - Journals
eISSN - 2450-7725
pISSN - 1509-5878
DOI - 10.24136/atest.2019.160
Subject(s) - battery (electricity) , lead–acid battery , plan (archaeology) , work (physics) , test plan , variable (mathematics) , computer science , mathematical model , voltage , reliability engineering , engineering , mathematics , electrical engineering , statistics , mechanical engineering , mathematical analysis , power (physics) , physics , archaeology , quantum mechanics , weibull distribution , history
The article describes the principle of the work of the lead-acid battery. The most common methods of assessing the technical condition of the battery were characterized and some causes of battery undercharging were indicated. The factors influencing the value of the battery voltage during the current load were indicated. An experimental plan was developed to determine the coefficients of a linear mathematical model describing the influence of individual independent variables on a dependent variable. A linear mathematical model was elaborated based on data obtained during battery tests in accordance with the adopted plan of the experiment.