z-logo
open-access-imgOpen Access
Corrosion Effects on Residual Structural Capacity of Resins / Exudates Inhibited Steel Reinforcement Flexural Beam
Author(s) -
Charles Kennedy,
Akpan Paul Paulinus,
Gbinu Samuel Kabari
Publication year - 2018
Publication title -
european journal of engineering and technology research
Language(s) - English
Resource type - Journals
ISSN - 2736-576X
DOI - 10.24018/ejeng.2018.3.5.693
Subject(s) - materials science , corrosion , ultimate tensile strength , flexural strength , composite material , deflection (physics) , elongation , beam (structure) , spall , structural engineering , physics , optics , engineering
The study investigated the effects of corrosion on the residual structural steel bar capacity of resins/exudates inhibited and non-inhibited reinforced concrete beam members. Steel reinforcements were coated with moringa oleifera lam resins/exudates from trees extract (Inorganic inhibitors), embedded into concrete beam members and exposed to sodium chloride medium representing laboratory harsh saline marine environment. Corrosion acceleration potential test was conducted on 27 samples of non-corroded, uncoated and coated resins/exudates paste thicknesses of steel bar and simulated for 60 days, after 30 days, initial concrete cured. Results obtained showed corrosion potential presence on uncoated members with cracks and spalling.  Further recorded results on non-corroded flexural strength test of failure load 29.09%, midspan deflection 28.30%, tensile strength 12.03% and elongation 31.50%, for coated beam members, failure load 29.42%, midspan deflection 27.42%, tensile strength 12.09% and elongation 31.80%, for corroded beam members, failure load decreased by 22.50%, midspan deflection increased by 39.30%, tensile strength decreased to 10.17% and elongation by increased 46.30%. The entire experimental results showed that corroded specimens has lower flexural load, higher midspan deflection, lower tensile strength and higher elongation due to loss of steel bar fibre from degradation effect from corrosion, inhibitors served as protective coating against corrosion, but no strength was added to steel members.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here