Computational and theoretical analysis of the fuel moisture influence on the fire-tube boiler unit efficiency at wood chips combustion
Author(s) -
V. A. Yakovlev,
Александр Осипов
Publication year - 2021
Publication title -
vestnik graždanskih inženerov
Language(s) - English
Resource type - Journals
ISSN - 1999-5571
DOI - 10.23968/1999-5571-2021-18-2-173-180
Subject(s) - boiler (water heating) , combustion , waste management , solid fuel , moisture , water content , engineering , thermal efficiency , environmental science , nuclear engineering , mechanical engineering , process engineering , materials science , chemistry , composite material , geotechnical engineering , organic chemistry
The article presents the results of a computational and theoretical analysis of the performance of the solid fuel boiler unit intended for wood chips combustion, the input fuel moisture content being of 10% to 50%. The authors consider the main design features of the solid fuel boiler unit equipped with a shielded furnace and fire-tube two-pass convective heating surfaces without turbulent movement intensifiers of combustion products. The influence of changes in the moisture content and the operating modes of the boiler unit on the main balance and operating values responsible for the thermal efficiency and economy of the boiler is analyzed.