A multi-center randomized controlled trial to compare a self-ligating bracket with a conventional bracket in a UK population: Part 1: Treatment efficiency
Author(s) -
Lian O'Dywer,
Simon Littlewood,
Shahla Rahman,
RickyJohn Spencer,
Sophy Barber,
Joanne S. Russell
Publication year - 2015
Publication title -
the angle orthodontist
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.116
H-Index - 86
eISSN - 1945-7103
pISSN - 0003-3219
DOI - 10.2319/112414837.1
Subject(s) - bracket , orthodontics , dentistry , center (category theory) , mathematics , randomized controlled trial , population , medicine , engineering , surgery , structural engineering , environmental health , chemistry , crystallography
Objective: To use a two-arm parallel trial to compare treatment efficiency between a self-ligating and a conventional preadjusted edgewise appliance system. Materials and Methods: A prospective multi-center randomized controlled clinical trial was conducted in three hospital orthodontic departments. Subjects were randomly allocated to receive treatment with either a self-ligating (3M SmartClip) or conventional (3M Victory) preadjusted edgewise appliance bracket system using a computer-generated random sequence concealed in opaque envelopes, with stratification for operator and center. Two operators followed a standardized protocol regarding bracket bonding procedure and archwire sequence. Efficiency of each ligation system was assessed by comparing the duration of treatment (months), total number of appointments (scheduled and emergency visits), and number of bracket bond failures. Results: One hundred thirty-eight subjects (mean age 14 years 11 months) were enrolled in the study, of which 135 subjects (97.8%) completed treatment. The mean treatment time and number of visits were 25.12 months and 19.97 visits in the SmartClip group and 25.80 months and 20.37 visits in the Victory group. The overall bond failure rate was 6.6% for the SmartClip and 7.2% for Victory, with a similar debond distribution between the two appliances. No significant differences were found between the bracket systems in any of the outcome measures. No serious harm was observed from either bracket system. Conclusions: There was no clinically significant difference in treatment efficiency between treatment with a self-ligating bracket system and a conventional ligation system.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom