Selection of the optimal medical waste incineration facility location: A challenge of medical waste risk management
Author(s) -
Kristina Stanojević,
Goran Radovanović,
Dragana Makajić-Nikolić,
Gordana Savić,
Barbara Simeunović,
Nataša Petrović
Publication year - 2020
Publication title -
vojnosanitetski pregled
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.123
H-Index - 19
eISSN - 2406-0720
pISSN - 0042-8450
DOI - 10.2298/vsp200521072s
Subject(s) - incineration , data envelopment analysis , facility location problem , environmental science , facility management , waste management , computer science , operations research , business , engineering , mathematics , mathematical optimization , marketing
Background/Aim. Among the other challenges of the 21st century, medical waste (MW) has become an arising problem for both the environment and people because of its increasing amount, variety, and complexity. That is way MW management has become one of the very important ecological imperatives. Serbia with no potential for appropriate disposal of all MW is forced to export MW to countries with MW incineration facilities. Incineration lowers the possible risks of inappropriate disposal and the emission of environmental pollutants, but leads to the need for a ?clever? choice of the incinerator facility location which has to meet diverse environmental, economic and technical criteria Methods. The criteria for the choice of optimal locations for a MW incinerator facility were as follows: the amount of MW that needs to be transported, the transport time from other locations, the current pollution of the location, the unemployment rate and the location safety in terms of natural disasters and accidents. By using the obtained results for seven efficient locations gained by Data Envelopment Analysis (DEA), we used a goal programming for the analysis of the most suitable location for a MW incineration facility. Results. In the proposed methodology on the chosen scenario and analysing the criteria relevant for selecting the most suitable location, using the DEA method, seven efficient locations for MW incineration facility were obtained. The optimal location was location 13. Conclusion. Based on the obtained results, we demonstrated that by the use of goal programming it is possible to develop a methodology for selection of optimal MW incineration facility location as one of the necessary activities of MW risk management.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom