Open Access
Numerical simulation on heating performance and emission characteristics of a new multi-stage dispersed burner for gas-fired radiant tubes
Author(s) -
Huanbao Fan,
Jianmin Feng,
Wei Bai,
Yujie Zhao,
Weidong Li,
Jun Gao,
Changpeng Liu,
Lina Jia
Publication year - 2022
Publication title -
thermal science/thermal science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.339
H-Index - 43
eISSN - 2334-7163
pISSN - 0354-9836
DOI - 10.2298/tsci210723323f
Subject(s) - nozzle , combustor , combustion , nox , materials science , thermal efficiency , combustion chamber , volumetric flow rate , analytical chemistry (journal) , nuclear engineering , chemistry , mechanics , thermodynamics , environmental chemistry , physics , organic chemistry , engineering
To enhance the temperature uniformity and NOx reduction performance of the gas-fired radiant tubes, we proposed a new multi-stage dispersed burner based on fuel-staging combustion technology in this study. The effect of fuel nozzle structural parameters, including secondary fuel nozzle distance D (30, 50, 70 mm), secondary fuel nozzle diameter ds (2, 3, 4, 5, 6 mm) and tertiary fuel nozzle diameter dt (2.5, 5, 7.5, 10 mm) on the flow field, temperature distribution, NOx generation and thermal efficiency were analyzed by numerical simulations. The results show that the multi-stage dispersed fuel nozzle could slow down the combustion rate and form a low-oxygen dilution zone in the reaction process, reducing the maximum combustion temperature and NOx emission. With the increase of the secondary fuel nozzle distance, the NOx concentration at the outlet decreased from 69.0 ppm to 54.6 ppm, and a decrease of 20.9%. When the secondary fuel nozzle diameter increased from 2 mm to 6 mm, the maximum wall temperature difference gradually increased 72.8 K to 76.3 K. NOx emission at the outlet first decreased, then increased, and was as low as 45.6 ppm at a 5 mm diameter. Furthermore, increasing the tertiary fuel nozzle diameter could reduce the maximum wall temperature difference and NOx emission, and improve thermal efficiency. When dt = 7.5 mm, the overall performance of the radiant tube was the best, and the outlet NOx concentration, wall temperature difference and thermal efficiency were 46.1 ppm, 73.0 K, 63.7%, respectively.