z-logo
open-access-imgOpen Access
Gantry orientation effect on the neutron and capture gamma ray dose equivalent at the maze entrance door in radiation therapy
Author(s) -
Hosein Ghiasi,
Asghar Mesbahi
Publication year - 2012
Publication title -
nuclear technology and radiation protection
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.31
H-Index - 16
eISSN - 1452-8185
pISSN - 1451-3994
DOI - 10.2298/ntrp1201070g
Subject(s) - isocenter , monte carlo method , neutron , electromagnetic shielding , physics , neutron capture , orientation (vector space) , gamma ray , nuclear medicine , nuclear physics , radiation , materials science , optics , medicine , mathematics , geometry , statistics , imaging phantom , quantum mechanics
In the present study, the effect of gantry orientation on the photoneutron and capture gamma dose calculations for maze entrance door was evaluated. A typical radiation therapy room made of ordinary concrete was simulated using MCNPX Monte Carlo code. Gantry rotation was simulated at eight different angles around the isocenter. Both neutron and capture gamma dose vary considerably with gantry angle. The ratios of the maximum to the minimum values for neutron and capture gamma dose equivalents were 1.9 and 1.4, respectively. On the other hand, comparison of the Monte Carlo calculated mean value over all orientations with Monte Carlo calculated neutron and gamma dose showed that the Wu-McGinley method differed by 5% and 2%, respectively. However, for more conservative shielding calculations, factors of 1.6 and 1.3 should be applied to the calculated neutron and capture gamma doses at downward irradiation. Finally, it can be concluded that the gantry angle influences neutron and capture gamma dose at the maze entrance door and it should be taken into account in shielding considerations

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here