An Ensemble LSTM Architecture for Clinical Sepsis Detection
Author(s) -
Sven Schellenberger,
Kilin Shi,
Jan P Wiedemann,
Fabian Lurz,
Robert Weigel,
Alexander Koelpin
Publication year - 2020
Publication title -
2019 computing in cardiology (cinc)
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.257
H-Index - 55
ISSN - 2325-887X
ISBN - 978-1-7281-6936-1
DOI - 10.22489/cinc.2019.297
Subject(s) - bioengineering , computing and processing , signal processing and analysis
Sepsis is a life-threatening condition that has to be treated at an early stage. Doctors use the Sequential Organ Failure Assessment score for the earliest possible recognition. In addition, the practitioner’s many years of experience help in order to facilitate an immediate response. Mortality decreases with every hour that sepsis is detected and treated with antibiotics. In this years PhysioNet/Computing in Cardiology Challenge the objective is to automatically detect sepsis six hours before the clinical prediction. This paper describes the implementation of an Long Short-Term Memory network for an early detection of sepsis in provided hourly physiological data. An utility score of 0.29 was achieved when testing on the full hidden test set. All entries were submitted using the team name "404: Sepsis not found".