
Effect of Different Lateral Reinforcement and its Spacing on Column Reinforced with Hollow Composite Sections
Author(s) -
Sneha Nair M D
Publication year - 2021
Publication title -
international journal for research in applied science and engineering technology
Language(s) - English
Resource type - Journals
ISSN - 2321-9653
DOI - 10.22214/ijraset.2021.38993
Subject(s) - brittleness , materials science , reinforcement , composite number , fibre reinforced plastic , composite material , core (optical fiber) , structural engineering , hccs , pier , engineering , cancer research , hepatocellular carcinoma , biology
Hollow Concrete Columns (HCCs) are one of the preferred construction systems in civil infrastructures including bridge piers, ground piles, and utility poles to minimize the overall weight and costs. HCCs are also considered a solution to increase the strength to mass ratio of structures. However, HCCs are subjected to brittle failure behaviour by concrete crushing means that the displacement capacity and the strength after steel yielding in HCCs are decreasing due to the unconfined concrete core. Absence of the concrete core changes the inner stress formation in HCCs from triaxial to biaxial causes lower strength. A new type of Hollow Composite Reinforcing System (HCRS) has recently been designed and developed to create voids in structural members. This reinforcing system has four external flanges to facilitate mechanical bonding and interaction with concrete. Therefore, providing the inner Hollow Composite Reinforced Sections (HCRS) can significantly increase strength by providing a higher reinforcement ratio and confining the inner concrete core triaxially. The corrosion of steel is also a notable factor in the case of steel reinforced HCCs which became more critical because their outer and inner surfaces exposing more concrete surface area. An alternative reinforcement is Glass Fibre Reinforced Polymer (GFRP) bars, can overcome the brittle behaviour of steel reinforced HCC. In previous studies, HCC shows high strength capacity, when appropriate reinforcement in the form of longitudinal GFRP bars, laterally using GFRP spirals and internally using rectangular HCRS which provide enough inner confinement. However, the spirals laterally restrict the expansion of the concrete core and limit the buckling of the longitudinal bars, allowing the columns to keep resisting applied loads and gives maximum strength. Therefore, in this study, the spirals are replaced by discrete hoops as lateral reinforcement to analyse the effect on structural behaviour of HCC reinforced with rectangle shaped HCRS under axial load using ANSYS software. The results show that column laterally reinforced with spiral attained insignificant increase in strength than their counterpart specimens confined with hoops. So, the circular hoops were found to be as efficient in confining concrete as spirals in a column reinforced internally with rectangle shaped HCRS. The increase in volumetric ratio can be achieved by reducing the spacing between lateral reinforcement. So, this study also investigates the effectiveness of reducing the spiral spacing in HCC reinforced with HCRS, three models with lateral spacing of 50mm, 40mm and 30mm are modelled and analysed. The results show that columns with closer spiral spacing attained more axial stability. Keywords: Hollow Concrete Column, Rectangular Hollow Composite Reinforced Sections, GFRP Spirals, GFRP Hoops, Nonlinear Static Analysis, ANSYS.