A Thermodynamic Performance Analysis of Triple Effect Vapour Absorption Refrigeration System Using LiBr-H2O
Author(s) -
S. H. Patel
Publication year - 2021
Publication title -
international journal for research in applied science and engineering technology
Language(s) - English
Resource type - Journals
ISSN - 2321-9653
DOI - 10.22214/ijraset.2021.38891
Subject(s) - condenser (optics) , absorption refrigerator , thermodynamics , refrigeration , nuclear engineering , cooling capacity , process engineering , vapor compression refrigeration , refrigerant , boiler (water heating) , renewable energy , absorption (acoustics) , materials science , exergy , environmental science , chemistry , engineering , heat exchanger , physics , electrical engineering , composite material , light source , optics
Being an eco-friendly system and a cheaper way to produce cooling effect absorption refrigeration system (ARS) is becoming more popular as it can produce higher cooling capacity than vapor compression refrigeration systems, and it can be powered by other sources of energy (like waste heat from gas and steam turbines, or can utilizes renewable source of heat by sun, geothermal, biomass) other than electricity. In the recent years, the interest in absorption refrigeration system is growing because these systems have environmentally friendly refrigerant and absorbent pairs. In this study, a detail energetic analysis of triple stage LiBr-H20 absorption system using First law of thermodynamics is done. An Energy Equation Solver code are used to simulate the computer program is developed for the cycle and results are validated with past studies available is also done. Mass, energy and exergy balance equations and the various complementary relations constitute the simulation model of the triple effect refrigeration system. Further, the effect of exit temperature of generator, absorber, condenser and evaporator on COP, solution concentration and other parameters are studied. It was found in the study that COP increases with increasing the generator exit temperature keeping the absorber exit temperature constant but when the absorber exit temperature is increased COP tends to decrease and the concentration of weak solution leaving HP generator (Xw3), MP generator (Xw2) and LP generator (Xw1) also increases with increase in generator exit temperature, while it decreases with increase in condenser exit temperature. Keywords: Absorption Refrigeration System (ARS), LiBr + H2O, COP, solution concentration, Energy Equation Solver code, energetic analysis, triple effect refrigeration system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here