z-logo
open-access-imgOpen Access
A SIMPLE AND RUGGED BIOANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF BRIVUDINE IN HUMAN PLASMA BY USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
Author(s) -
S Satheshkumar,
V Muruganantham
Publication year - 2020
Publication title -
international journal of pharmacy and pharmaceutical sciences
Language(s) - English
Resource type - Journals
eISSN - 2656-0097
pISSN - 0975-1491
DOI - 10.22159/ijpps.2020v12i7.37703
Subject(s) - chromatography , bioanalysis , phosphoric acid , analyte , chemistry , high performance liquid chromatography , detection limit , accuracy and precision , human plasma , extraction (chemistry) , linearity , methanol , analytical chemistry (journal) , mathematics , statistics , physics , organic chemistry , quantum mechanics
Objective: The current research work focus to simple and rugged bioanalytical method development and validation of brivudine in human plasma using high-performance liquid chromatography. Methods: The analyte (Brivudine) and internal standard (Sofosbuvir) were extracted using the Solid Phase Extraction (SPE) technique. The chromatographic separation was accomplished by using Zorbax eclipse XDB-C18 Column (150×4.6 mm, 5 μm) with a mobile phase consisted of Methanol: 0.5% Ortho-phosphoric acid (65:35%, v/v) respectively, at a flow rate of 0.7 mL/min. The developed method was validated by performing system suitability, carryover effect, linearity, selectivity, sensitivity, precision, accuracy, recovery, ruggedness, and stability studies. The method was validated as per USFDA guidelines. Results: The selected chromatographic condition was found to efficiently separated brivudine (RT-3.55 min) and ISTD (RT-7.87 min). The assay demonstrated a linear dynamic range of 85.205 to 4500.246 ng/ml for brivudine in human plasma with r2>0.99. Demonstrated the lowest limit of detection at 85.205 ng/ml. This method established an intra-run and inter-run precision within the range of 2.99-6.31%CV and 3.67-5.80%CV, respectively. Additional intra-run and inter-run accuracy were within the range of 97.55-105.37% and 99.27-102.15%, respectively. The mean percentage recovery of brivudine and ISTD studies proved good extraction efficiency and the robustness was also evaluated. Conclusion: A simple, accurate, precise, linear and rugged RP-HPLC method was developed and validated for the estimation of brivudine in human plasma with K2EDTA anticoagulant and suitable for conducting BA/BE and TDM.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Empowering knowledge with every search

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom