Open Access
SIMULTANEOUS ESTIMATION OF MOMETASONE FUROATE AND FORMOTEROL FUMARATE BY HPLC METHOD IN ROTACAPS
Author(s) -
Aarti Zanwar,
Dhanya B. Sen,
Ashim Kumar Sen,
A. K. Seth
Publication year - 2018
Publication title -
international journal of pharmacy and pharmaceutical sciences/international journal of pharmacy and pharmaceutical sciences
Language(s) - English
Resource type - Journals
eISSN - 2656-0097
pISSN - 0975-1491
DOI - 10.22159/ijpps.2019v11i2.24799
Subject(s) - chromatography , repeatability , mometasone furoate , detection limit , chemistry , reproducibility , high performance liquid chromatography , relative standard deviation , acetonitrile , dosage form , formoterol , medicine , budesonide , corticosteroid , surgery
Objective: To develop and validate a simple and sensitive RP-HPLC method for the simultaneous determination of mometasone furoate (MOM) and formoterol fumarate (FOR) in pharmaceutical dosage forms.
Methods: In RP-HPLC method, chromatographic separation was achieved using a mixture of a solvent system consisting of methanol–water (pH 3.5) in the ratio of 85:15 % v/v at a flow rate of 1 ml/min and detection was carried out at 225 nm.
Results: The run time for the simultaneous estimation of drugs for the proposed method was 10 min as drugs eluted at 5.217 min (MOM) and 8.650 min (FOR). The linearity was found in the range of 33.33-299.97 μg/ml and 1-9 μg/ml for MOM and FOR, respectively. The values of limit of detection and limit of quantification were 3.634, 0.266 µg/ml and 11.014, 0.807 µg/ml, which indicates the sensitivity of the method for the estimation of MOM and FOR, respectively. The results of recovery studies for both the drugs were within the range i.e. 98.87-101.48 % which indicates the accuracy of the method. Relative standard deviation obtained from repeatability and reproducibility studies were less than 2% indicates the precision of the method. The proposed method was validated according to ICH guidelines.
Conclusion: The proposed RP-HPLC method was found to be sensitive and precise because of the low LOD, LOQ and % RSD values (<2). The proposed work does not require acetonitrile and ion pairing reagent as compared to the reported methods. Therefore, method can be used preferably for routine analysis due to its simplicity and economic advantages.