z-logo
open-access-imgOpen Access
ANALYTICAL METHOD BY HPLC-DAD ALLOWS QUANTIFICATION OF QUERCETIN MARKER IN STANDARDIZED EXTRACT OF ANADENANTHERA COLUBRINA VAR. CEBIL
Author(s) -
Valmir Gomes de Souza,
Fabrício Havy Dantas de Andrade,
Fábio Santos de Souza,
Rui Oliveira Macêdo
Publication year - 2017
Publication title -
international journal of pharmacy and pharmaceutical sciences/international journal of pharmacy and pharmaceutical sciences
Language(s) - English
Resource type - Journals
eISSN - 2656-0097
pISSN - 0975-1491
DOI - 10.22159/ijpps.2017v9i8.16468
Subject(s) - quercetin , chromatography , maceration (sewage) , detection limit , high performance liquid chromatography , chemistry , flavonoid , traditional medicine , antioxidant , medicine , biochemistry , materials science , composite material
Objective: The Anadenanthera colubrina (Vell.) Brennan var. cebil is a medicinal plant that has been used for the treatment of many diseases in the northeastern region of Brazil. This plant contains secondary metabolites such as quercetin, a flavonoid that is known by its antioxidant and anti-inflammatory effects. The aim of this work is to propose the validation of an analytical method using high-performance liquid chromatography with diode array detector (HPLC-DAD) for the quantification of quercetin and standardization of the hydroalcoholic extract (HAE) of A. colubrina.Methods: The A. colubrina extracts were prepared by the maceration process with powdered leaves at 20% weight: volume (w/v) and a hydroalcoholic solution at 50% volume: volume (v/v) for 120 h at room temperature. After pretreatment of the hydroalcoholic extract, the quercetin marker was used for quantification and proceeded to the evaluation of validation parameters for the method using HPLC-DAD.Results: The analytical method proved to be specific. Linear over the range 1.4–26.6 µg/ml, regression analysis showed a good correlation coefficient (R2= 0.999); the limit of detection (LOD) and the limit of quantification (LOQ) were 0.27 and 0.81 μg/ml respectively. The relative standard deviation (RSD) did not exceed 2.5% for precision. The proposed method was validated with an average recovery of 92.5–97.5%.Conclusion: The method was validated using HPLC-DAD, allowing the quantification of quercetin in the standardisation process of extracts and quality control of the herbal drug containing A. colubrina Phyto complex.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here