THE EFFECT OF PVC-BASED MEMBRANE COMPOSITION AND Zn(II), Cd(II) AND Pb(II) INTERFERING IONS TO Hg(II) ION SELECTIVE ELECTRODE (ISE) PERFORMANCE BY USING DBA<sub>2</sub>18C6 IONOPHORE
Author(s) -
Abd Wahab
Publication year - 2010
Publication title -
indonesian journal of chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.273
H-Index - 14
eISSN - 2460-1578
pISSN - 1411-9420
DOI - 10.22146/ijc.21768
Subject(s) - chemistry , nuclear chemistry , ionophore , composition (language) , membrane , ion , potassium , analytical chemistry (journal) , chromatography , philosophy , biochemistry , linguistics , organic chemistry
The effect of PVC (Polyvinylchloride)-Based Membrane Composition to Ion Selective Electrode (ISE)-Hg(II) Performance using Ionophore DBA218C6 (N,N'-Dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclo octadecane),  Plasticizer NPOE (Nitrophenyl Octhyl Ether), Anionic Site KTCPB (Potassium Tetrakis (4-chloro phenyl) borate) have been performed. Membrane compositions used were:(a) PVC (30 mg), NPOE (60 mg), DBA218C6(6 mg) and KTCPB (4 mg); (b) PVC(30 mg), NPOE (60 mg), DBA218C6(7 mg) and KTCPB (3 mg); (c) PVC (30 mg), NPOE (59 mg), DBA218C6 (8 mg) and KTCPB( 3 mg). The concentration range of interference ions Zn(II), Cd(II) and Pb(II)  were 1.0 x 10-3 - 1.0 x 10-1 M. ISE-Hg(II) performance for membrane composition of 30 : 60 : 6 : 4 was 26.34 mV per decade (Nernstian Slope value) on Hg(II) concentration range of 1.0x10-6 - 1.0 x 10-1 M , membrane composition of 30 : 60 : 7 : 3 was 27.71 mV per decade on Hg(II) concentration range of 1.0 x10-6 - 1.0 x10-1 M, and membrane composition of 30 : 59 : 8 : 3 was 28.52 mV per decade on Hg(II) concentration range of  1.0 x10-6 - 1.0 x10-1 M with activity between pH 1.0-3.0. The concentration of interference ions : Zn(II), Cd(II) and Pb(II) in the range of 1.0 x 10-3 - 1.0 x 10-1 M with the ratio of the primary ion to interference ions of 4 : 1 gave real effect. As results, selectivities and sensitivities between ISE-Hg(II) and Ionophore DBA218C6 could be determined by PVC-Based Membrane Composition and the effect of Zn(II), Cd(II) and Pb(II)  interference ions was observed in the concentration of 1,0 x10-3 - 1,0 x10-1 M.   Keywords: membrane composition effect, ionophore DBA218C6, ISE-Hg(II)

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom