z-logo
open-access-imgOpen Access
Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
Author(s) -
Maartje M S Hendriks,
Jaap H. van Lotringen,
Marije Vos-van der Hulst,
Noël Keijsers
Publication year - 2021
Publication title -
jmir mhealth and uhealth
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.356
H-Index - 50
ISSN - 2291-5222
DOI - 10.2196/24339
Subject(s) - medicine , rehabilitation , stroke (engine) , heart rate , physical therapy , spinal cord injury , physical medicine and rehabilitation , anesthesia , spinal cord , blood pressure , mechanical engineering , psychiatry , engineering
Background Since adequate sleep is essential for optimal inpatient rehabilitation, there is an increased interest in sleep assessment. Unobtrusive, contactless, portable bed sensors show great potential for objective sleep analysis. Objective The aim of this study was to investigate the feasibility of a bed sensor for continuous sleep monitoring overnight in a clinical rehabilitation center. Methods Patients with incomplete spinal cord injury (iSCI) or stroke were monitored overnight for a 1-week period during their in-hospital rehabilitation using the Emfit QS bed sensor. Feasibility was examined based on missing measurement nights, coverage percentages, and missing periods of heart rate (HR) and respiratory rate (RR). Furthermore, descriptive data of sleep-related parameters (nocturnal HR, RR, movement activity, and bed exits) were reported. Results In total, 24 participants (12 iSCI, 12 stroke) were measured. Of the 132 nights, 5 (3.8%) missed sensor data due to Wi-Fi (2), slipping away (1), or unknown (2) errors. Coverage percentages of HR and RR were 97% and 93% for iSCI and 99% and 97% for stroke participants. Two-thirds of the missing HR and RR periods had a short duration of ≤120 seconds. Patients with an iSCI had an average nocturnal HR of 72 (SD 13) beats per minute (bpm), RR of 16 (SD 3) cycles per minute (cpm), and movement activity of 239 (SD 116) activity points, and had 86 reported and 84 recorded bed exits. Patients with a stroke had an average nocturnal HR of 61 (SD 8) bpm, RR of 15 (SD 1) cpm, and movement activity of 136 (SD 49) activity points, and 42 reported and 57 recorded bed exits. Patients with an iSCI had significantly higher nocturnal HR ( t 18 =−2.1, P =.04) and movement activity ( t 18 =−1.2, P =.02) compared to stroke patients. Furthermore, there was a difference between self-reported and recorded bed exits per night in 26% and 38% of the nights for iSCI and stroke patients, respectively. Conclusions It is feasible to implement the bed sensor for continuous sleep monitoring in the clinical rehabilitation setting. This study provides a good foundation for further bed sensor development addressing sleep types and sleep disorders to optimize care for rehabilitants.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.