z-logo
open-access-imgOpen Access
Validation of mathematical model of electrothermal calculation of DC catenary on the basis of scale model
Author(s) -
Alexander Viktorovich Paranin,
Andrey Borisovich Batrashov
Publication year - 2018
Publication title -
vestnik naučno-issledovatelʹskogo instituta železnodorožnogo transporta/vestnik naučno-issledovatelʹskogo instituta železnodorožnogo transporta
Language(s) - English
Resource type - Journals
eISSN - 2713-2560
pISSN - 2223-9731
DOI - 10.21780/2223-9731-2018-77-4-222-229
Subject(s) - catenary , current (fluid) , scale model , mechanics , structural engineering , scale (ratio) , finite element method , allowance (engineering) , cross section (physics) , engineering , mechanical engineering , electrical engineering , physics , quantum mechanics , aerospace engineering
The article compares the results of calculation of the finite element simulation of current and temperature distribution in the scale model of the DC catenary with the data of laboratory tests. Researches were carried on various versions of the structural design of catenary model, reflecting the topological features of the wire connection, characteristic of the DC contact network. The proportions of the cross-sectional area of the scaled model wires are comparable to each other with the corresponding values for real DC catenary. The article deals with the operating conditions of the catenary model in the modes of transit and current collection. When studying the operation of the scale catenary model in the transit mode, the effect of the structural elements on the current distribution and heating of the wires was obtained. Within the framework of the scale model, theoretical assumptions about the current overload of the supporting cable near the middle anchoring have been confirmed. In the current collection mode, the experimental dependences of the current in the transverse wires of the scale model are obtained from the coordinate of the current collection point. Using the model it was experimentally confirmed that in the section of the contact wire with local wear, not only the temperature rise occurs but also the current redistribution due to the smaller cross section. Thus, the current share in other longitudinal wires of the scale model increases and their temperature rises. Scale and mathematical models are constructed with allowance for laboratory clamps and supporting elements that participate in the removal of heat from the investigated wires. Obtained study results of the scale model allow to draw a conclusion about the adequacy of the mathematical model and its correspondence to the real physical process. These conclusions indicate the possibility of applying mathematical model for calculating real catenary, taking into account the uneven contact wear wire and the armature of the contact network.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here