Analysis of the functional dependability of underground gas storage compressor stations in cases when actual performance indicators deviate from the design values
Author(s) -
Mikhail A. Vorontsov,
A. S. Grachiov,
A. O. Grachiova,
M. A. Kirkin,
A. V. Melnikova
Publication year - 2022
Publication title -
nadëžnostʹ
Language(s) - English
Resource type - Journals
eISSN - 2500-3909
pISSN - 1729-2646
DOI - 10.21683/1729-2646-2022-22-1-44-51
Subject(s) - dependability , gas compressor , reliability engineering , reciprocating compressor , computer science , unit (ring theory) , centrifugal compressor , gas turbines , engineering , mechanical engineering , mathematics , mathematics education
Aim. The paper examined the matter of assessment of the functional dependability of compressor stations (CS) of underground gas storage (UGS) facilities. A definition of CS functional dependability and guidelines for its assessment were proposed. Methods. Design calculation of compressor stations, scenario analysis. Results. The paper presents: a) a definition, indicators of CS functional dependability and guidelines for its assessment; b) an example of the guidelines application for UGS CS; c) a comparative analysis of UGS CS functional dependability in a number of various versions: use of single-unit and two-unit centrifugal compressors as part of gas turbine gas pumping units for two-stage compression with intercooling. Conclusion. The paper shows the requirement to analyse the functional dependability of various versions of UGS CS for the purpose of identifying the most rational option that ensures unconditional performance of the key UGS CS function under uncertain initial design data.