Open Access
Laboratory Calibration Procedures of the Hydra Probe Soil Moisture Sensor:Infiltration Wet‐Up vs. Dry‐Down
Author(s) -
Burns Travis T.,
Adams Justin R.,
Berg Aaron A.
Publication year - 2014
Publication title -
vadose zone journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.036
H-Index - 81
ISSN - 1539-1663
DOI - 10.2136/vzj2014.07.0081
Subject(s) - infiltration (hvac) , water content , calibration , mean squared error , moisture , environmental science , soil science , soil water , remote sensing , mathematics , geology , materials science , geotechnical engineering , statistics , composite material
Impedance probes are popular electromagnetic soil moisture monitoring devices used for a variety of applications but require site‐specific calibrations to provide accurate measurements. Several calibration techniques have been reported in the literature, although laboratory‐based procedures involving wet‐up (via upward or downward infiltration) and dry‐down are commonly performed for permanently installed sensors. Wet‐up calibrations can be completed substantially faster (<1 d) than dry‐down calibrations (1–2 wk), but it is uncertain which technique is preferable to provide the most accurate calibration. The objective of this study was to compare the results obtained from laboratory‐based infiltration wet‐up and dry‐down calibrations of the Stevens Hydra Probe soil moisture sensor. Soil samples for this study were obtained from agricultural sites in Saskatchewan, Canada, at depths of 5, 20, and 50 cm across a variety of textural compositions. Results demonstrate that utilizing either infiltration wet‐up (according to the procedure in this study) or dry‐down procedures provides accuracies of <0.061 m 3 m −3 root mean square error (RMSE), which was superior to manufacturer calibration accuracy across all samples. However, superior calibration accuracies (i.e., the lowest RMSE) were achieved using the dry‐down procedure across all soil samples, resulting in a lower RMSE of 0.01 to 0.04 m 3 m −3 (at 95% confidence). A significant correlation ( r value = 0.61, p < 0.05) exists between the differences in infiltration wet‐up and dry‐down calibration RMSEs and clay content. This suggests that the difference between the two procedures tested in this study is more significant in finer textured soils. The findings of this study indicate that the dry‐down procedure produced the lowest RMSE and is therefore the preferred calibration procedure, particularly for finer textured soils.