Subject(s) - reflectometry , vadose zone , thermal diffusivity , porosity , saturation (graph theory) , soil science , thermal conductivity , soil water , water content , bulk density , gravimetric analysis , volumetric heat capacity , materials science , time domain , mineralogy , environmental science , chemistry , heat flux , heat transfer , geology , composite material , geotechnical engineering , thermodynamics , physics , mathematics , organic chemistry , combinatorics , computer science , computer vision
Soil and environmental studies in the vadose zone are often restricted by the lack of equipment that can measure the variation of soil physical parameters in space and time. In this paper we demonstrate that thermo‐time domain reflectometry (thermo‐TDR) can be used for a wide range of soil physical measurements. The thermo‐TDR probe combines TDR and heat‐pulse technologies into a single probe. It allows measurements of volumetric soil water content (θ), temperature ( T ), electrical conductivity (EC), thermal conductivity (λ), thermal diffusivity (α), and volumetric heat capacity (ρ c ) at the same sampling positions simultaneously. Furthermore, other soil physical parameters, such as bulk density (ρ b ), air‐filled porosity ( n a ), and degree of saturation ( S ), can be determined from their relationships with ρ c and θ. We examined the performance of the thermo‐TDR using both published data and laboratory measurements on packed columns and intact cores from six soils of varying texture. The results show that the thermo‐TDR provides reliable measurements of θ, EC, ρ c , λ, n a , and S , but relatively large errors exist in ρ b The average standard error between thermo‐TDR measurements and gravimetric measurements is 0.026 m 3 m −3 for θ, 0.050 m 3 m −3 for n a , 0.069 for S , and 0.134 Mg m −3 for ρ b The standard error between thermo‐TDR measurements and theoretical predictions of ρ c is 0.134 MJ m −3 K −1 These promising findings coupled with the characteristics of small probe size and easy automation make the thermo‐TDR sensor an ideal tool for studying coupled flow processes in the vadose zone. Further improvements in probe design, waveform interpretation, and determination of effective probe length are also noted as steps toward improving accuracy and precision of future thermo‐TDR measurements.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here