z-logo
Premium
Small Spatial Scale Soil Water Content Measurement with Time‐Domain Reflectometry
Author(s) -
Amato M.,
Ritchie J. T.
Publication year - 1995
Publication title -
soil science society of america journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.836
H-Index - 168
eISSN - 1435-0661
pISSN - 0361-5995
DOI - 10.2136/sssaj1995.03615995005900020008x
Subject(s) - reflectometry , loam , water content , soil science , soil water , subsoil , environmental science , spatial variability , saturation (graph theory) , gravimetric analysis , hydrology (agriculture) , time domain , geology , chemistry , mathematics , geotechnical engineering , computer science , computer vision , statistics , organic chemistry , combinatorics
Plants growing on stored soil water often exhibit symptoms of water deficit even though a relatively large quantity of soil water is available for uptake where roots are present in the subsoil. To explore the possibility that this less effective absorption phenomenon was related to nonuniform root distribution or root clumping around soil peds, we examined the suitability of time‐domain reflectometry for measuring soil water content distribution on a small spatial scale. Measurements were made on clay loam and sandy clay soils with 21‐mm‐long parallel balanced transmission lines and compared with gravimetric water content measurement. Water content values ranged from oven dry to saturation. To quantify the error in propagation time measurement using short transmission lines, measurements were made in air using rod lengths ranging from 10 to 150 mm. The coefficient of variation was quite high (2.8–7.3%) for times shorter than 100 ps for air‐dry soil. In this case, the technique proved less reliable. For longer times, corresponding to higher water contents, the coefficient of variation was <3%. A few samples of clay loam soil with water contents >0.29 m 3 m −3 showed excessively high values of dielectric constant. Care should be taken in data interpretation at high water content for these media. Time‐domain reflectometry proved effective in measuring water content with the tested transmission line for values >0.07 m 3 m −3 . Thus, a tool is provided for in situ measurement of spatial variability or at a spatial scale compatible with many problems ranging from the water uptake of clustered roots to seed germination in the field.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here