z-logo
Premium
Sample Preparation for Determining Ions in Dark Colored Sodic Soil Extracts
Author(s) -
Robbins Charles W.
Publication year - 1989
Publication title -
soil science society of america journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.836
H-Index - 168
eISSN - 1435-0661
pISSN - 0361-5995
DOI - 10.2136/sssaj1989.03615995005300030013x
Subject(s) - chemistry , atomic absorption spectroscopy , spectrophotometry , formate , potentiometric titration , organic matter , adsorption , chromatography , bicarbonate , nuclear chemistry , inorganic chemistry , ion , organic chemistry , physics , quantum mechanics , catalysis
Saturation paste extracts of sodic soils (pH >8.5 and electrical conductivity <4.0 dS m −1 ) usually contain dark colored, suspended organic matter that interferes with colorimetric, turbidimetric, potentiometric, ion chromatographic (IC) and to a lesser extent, atomic absorption spectrophotometry and flame emission procedures. Bicarbonate also interferes with formate analysis by IC in those extracts. This study was conducted to develop a simple pretreatment method for removing those interferences without introducing new interferences. Fifteen mL extract samples were titrated to pH 8.4, then to 4.7 and finally to a pH range of 3.0 to 3.5 with standardized H 2 SO 4 or HCl. The first two end points determine CO 2‐ 3 and HCO ‐ 3 concentrations. The third pH adjustment removed the HCO ‐ 3 interference from the formate analysis and allowed for organic matter coagulation. The acid choice depended on whether Cl ‐ or SO 2‐ 4 was to be measured later. To remove the organic matter, the extracts were contrifuged and forced through a 0.2‐µm nylon filter following 0.08 M AlCl 3 or 0.04 M Al 2 (SO 4 ) 3 treatments. Formate and acetate concentrations were determined by IC. The Cl ‐ concentrations were determined by colorimetric, and IC procedures. The SO 2‐ 4 concentrations were measured turbidimetrically and by IC. The extracts were analyzed for Ca 2+ and Mg 2+ by atomic adsorption spectrophotometry, and Na + and K + by flame emission. Titrating the extracts as described provided CO 2‐ 3 and HCO ‐ 3 data, removed the HCO ‐ 3 interference from the formate analysis, and allowed Al 3+ to coagulate the suspended organic matter, which was then removed by centrifugation and filtration. This pretreatment did not interfere with any of the analytical methods tested, except for cation determination by IC and anion determination by IC when methyl orange was used as a pH end point indicator.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here