z-logo
Premium
The Effects of Dosed versus Gravity‐Fed Loading Methods on the Performance and Reliability of Contour Trench Disposal Fields Used for Onsite Wastewater Treatment
Author(s) -
BridsonPateman Evan,
Hayward Jennifer,
Jamieson Rob,
Boutilier Leah,
Lake Craig
Publication year - 2013
Publication title -
journal of environmental quality
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 171
eISSN - 1537-2537
pISSN - 0047-2425
DOI - 10.2134/jeq2012.0255
Subject(s) - trench , effluent , wastewater , clogging , environmental science , hydraulics , environmental engineering , waste disposal , sewage treatment , water quality , hydrology (agriculture) , geology , geotechnical engineering , waste management , engineering , chemistry , ecology , layer (electronics) , biology , history , aerospace engineering , organic chemistry , archaeology
In Nova Scotia, Canada, contour trench disposal fields are the most common type of onsite wastewater system. In this study, two identical contour trench disposal fields were monitored for 3 yr to compare performance under gravity‐fed versus periodically dosed loading conditions. Influent and effluent from both systems were analyzed for a suite of water quality parameters, and the hydraulics of the systems were assessed using tracer studies and measurements of ponded water depth in the distribution trenches. Ponded water depths in the distribution trench of the gravity‐fed disposal field were observed to increase steadily during the monitoring period, indicating progressive clogging. This was not observed in the periodically dosed field. Regarding treatment, both systems performed well, consistently producing effluent with 5‐d biochemical oxygen demand and total suspended solids (TSS) concentrations <10 mg L −1 and achieving >5 log reductions in Escherichia coli . However, the gravity‐fed system produced statistically lower average effluent concentrations for total P and TSS. It is speculated that the slightly better treatment performance achieved by the gravity‐fed system is due to enhanced biomat formation. This study demonstrated adequate treatment of residential wastewater by contour trench disposal fields regardless of loading method. However, because the hydraulic performance of these systems is heavily dependent on pretreatment and loading methods, it is recommended that a dosing system be used to distribute wastewater to contour trench disposal fields to help prevent hydraulic failure.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here