z-logo
open-access-imgOpen Access
Power management of variable capacitors in electrical grid systems according to the criterion of mini-mum energy loss
Author(s) -
S. S. Girshin,
E. G. Andreeva,
K. V. Khatsevskiy,
V. M. Trotsenko,
N. А. Melnikov,
Е. В. Петрова,
V. N. Goryunov
Publication year - 2022
Publication title -
vestnik irkutskogo gosudarstvennogo tehničeskogo universiteta
Language(s) - English
Resource type - Journals
eISSN - 2500-1590
pISSN - 1814-3520
DOI - 10.21285/1814-3520-2021-6-741-752
Subject(s) - capacitor , battery (electricity) , electrical engineering , control theory (sociology) , ac power , power (physics) , energy (signal processing) , grid , engineering , computer science , mathematics , voltage , physics , statistics , geometry , control (management) , quantum mechanics , artificial intelligence
The aim is to manage the transmitted reactive power in electrical grids using variable capacitor batteries according to the criterion of minimum energy loss under different annual reactive load schedules and different numbers of variable capacitor sections. The main theoretical relations were obtained by the methods of mathematical modelling and integral calculus using the theory of optimal control. The influence of the power and number of sections in a capacitor battery on energy losses in the grid was estimated using computational experiments. Dependencies for energy losses in a capacitor battery, as well as for reducing energy losses in the grid, were obtained. These expressions are valid for linearized load schedules. It is shown that the dependences of energy losses in a capacitor battery and the reduction of losses in the grid on the section power have inflection points and pass through a maximum. The presence of inflection points is associated with a change in the number of capacitor sections operating throughout the year. The presence of a maximum is explained by the fact that, with an increase in the power of the capacitor battery, its operating time decreases under the complete number of variable sections. It is established that the batteries of static capacitors with two variable sections can reduce energy losses when transmitting reactive power by over 90%. For three- and four-section static capacitors, the loss reduction is close to 100%. The reduction in energy losses increases when approaching maximal levels of annual reactive load. Energy losses in electrical grid systems can be reduced by capacitor batteries with no more than three or four variable sections. In most cases, this can be achieved by two-section capacitor batteries.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here