z-logo
open-access-imgOpen Access
Body coil reference for inverse reconstructions of multi-coil data—the case for real-time MRI
Author(s) -
Dirk Voit,
Oleksandr Kalentev,
Jens Frahm
Publication year - 2019
Publication title -
quantitative imaging in medicine and surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.766
H-Index - 21
eISSN - 2223-4292
pISSN - 2223-4306
DOI - 10.21037/qims.2019.08.14
Subject(s) - electromagnetic coil , computer science , inverse problem , algorithm , fast fourier transform , inverse , fourier transform , iterative reconstruction , phase (matter) , artificial intelligence , mathematics , physics , mathematical analysis , geometry , quantum mechanics
Real-time magnetic resonance imaging (MRI) or model-based MRI reconstructions of parametric maps require the solution of an ill-posed nonlinear inverse problem. Respective algorithms, e.g., the iteratively regularized Gauss-Newton method, implicitly combine datasets from multiple receive coils. Because these local coils may exhibit complex sensitivity profiles with rather different phase offsets, the numerical optimization may lead to phase singularities which in turn cause "black holes" in magnitude images. The purpose of this work is to develop a method for inverse reconstructions of multi-coil MRI data which avoids the generation of such spatially selective phase singularities. It is proposed to use volumetric body coil data and start the iterative reconstruction of multi-coil data with a reference image which offers proper phase information. In more detail, inverse reconstructions of multi-coil data are initialized with a complex "seed" image which is obtained by a Fast Fourier Transform (FFT) reconstruction of data from a single body coil element. This is accomplished at no additional cost as only very few body coil scans with identical conditions as the multi-coil acquisitions are needed as part of the regular prep scan period. The method is evaluated for anatomical real-time MRI and model-based phase-contrast flow MRI in real-time at 3 T. The proposed method overcomes phase singularities in all cases for arbitrary sets of receive coils. In conclusion, the automatic use of a single body coil reference image is simple, robust, and further improves the reliability of advanced MRI reconstructions from multi-coil data.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here