The use of plasmakinetic cautery compared to conventional electrocautery for dissection of abdominal free flap for breast reconstruction: single-centre, randomized controlled study
Author(s) -
Whitney Chow,
Georgette Oni,
Venkat Ramakrishnan,
Mat Griffiths
Publication year - 2019
Publication title -
gland surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.643
H-Index - 22
eISSN - 2227-8575
pISSN - 2227-684X
DOI - 10.21037/gs.2018.12.04
Subject(s) - medicine , seroma , diathermy , surgery , dissection (medical) , cauterization , electrocoagulation , complication
The plasmakinetic cautery is a surgical dissection instrument that combines scalpel-like cutting precision with electrocautery-like haemostasis properties, and operates at lower temperatures (40-170 °C) than conventional electrocautery (200-350 °C). The aim of this study is to evaluate the clinical benefits of using plasmakinetic cautery in abdominal free flap dissection for breast reconstruction.