Open Access
Quasi-Static Compliance Calibration of Serial Articulated Industrial Manipulators
Author(s) -
Nikolas Alexander Theissen,
Monica Katherine Gonzalez,
Asier Barrios,
Andreas Archenti
Publication year - 2021
Publication title -
international journal of automation technology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.513
H-Index - 18
eISSN - 1883-8022
pISSN - 1881-7629
DOI - 10.20965/ijat.2021.p0590
Subject(s) - quasistatic process , control theory (sociology) , workspace , static analysis , stiffness , longitudinal static stability , computer science , robot , engineering , structural engineering , physics , mechanics , artificial intelligence , control (management) , quantum mechanics , aerodynamics
This article presents a procedure for the quasi-static compliance calibration of serial articulated industrial manipulators. Quasi-static compliance refers to the apparent stiffness displayed by manipulators at low-velocity movements, i.e., from 50 to 250 mm/s. The novelty of the quasi-static compliance calibration procedure lies in the measurement phase, in which the quasi-static deflections of the manipulator’s end effector are measured under movement along a circular trajectory. The quasi-static stiffness might be a more applicable model parameter, i.e., representing the actual manipulator more accurately, for manipulators at low-velocity movements. This indicates that the quasi-static robot model may yield more accurate estimates for the trajectory optimization compared with static stiffness in the implementation phase. This study compares the static and apparent quasi-static compliance. The static deflections were measured at discretized static configurations along circular trajectories, whereas the quasi-static deflections were measured under circular motion along the same trajectories. Loads of different magnitudes were induced using the Loaded Double Ball Bar. The static and quasi-static displacements were measured using a linear variable differential transformer embedded in the Loaded Double Ball Bar and a Leica AT901 laser tracker. These measurement procedures are implemented in a case study on a large serial articulated industrial manipulator in five different positions of its workspace. This study shows that the measured quasi-static deflections are bigger than the measured static deflections. This, in turn, indicates a significant difference between the static and apparent quasi-static compliance. Finally, the implementation of the model parameters to improve the accuracy of robots and the challenges in realizing cost-efficient compliance calibration are discussed.