z-logo
open-access-imgOpen Access
ANALISIS PERBANDINGAN KINERJA SISTEM DISTRIBUSI PANAS PADA VARIASI RUANG MESIN PENGERING IKAN
Author(s) -
Ahmad Aryadillah,
Aqli Mursadin
Publication year - 2016
Publication title -
scientific journal of mechanical engineering kinematika
Language(s) - English
Resource type - Journals
eISSN - 2655-903X
pISSN - 2655-9048
DOI - 10.20527/sjmekinematika.v1i1.25
Subject(s) - airflow , tube (container) , materials science , environmental science , air temperature , nuclear engineering , mechanical engineering , mechanics , composite material , engineering , physics , meteorology
The purpose of this research is to know the heat distribution system in three types of fish dryers. The variations of the dryer room were fire-tube type, fire-tube type with bevel, and air-tube type. This study was conducted by simulating airflow and heat transfer that occurred in each dryer room variation by using CFD software. In the simulation, the dryer was heated using an electric heating element with a temperature of 80 °C and the results display hot air flow moving in the drying chamber. In the fire-tube type dryer room obtained average temperature of 46.74OC. In the fire-tube type dryer room with the bevel obtained an average temperature of 44.40OC. While the type of air-tube shows average temperature results of 34.31OC. From the simulation, we known that the fire-tube type has the best heat distribution system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here