z-logo
Premium
Development and Evaluation of an aquatic ecological risk assessment system (KORECORisk) for the management of industrial complexes
Author(s) -
Lee YongJu,
Kim YongHwa,
Kim Kyun,
Lee DongSoo
Publication year - 2007
Publication title -
integrated environmental assessment and management
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.665
H-Index - 57
eISSN - 1551-3793
pISSN - 1551-3777
DOI - 10.1897/ieam_2007-008.1
Subject(s) - estimation , risk assessment , environmental science , aquatic ecosystem , risk management , computer science , environmental resource management , risk analysis (engineering) , biochemical engineering , ecology , business , biology , engineering , systems engineering , computer security , finance
KORea ECOlogical Risk assessment (KORECORisk) was developed to support decision making for the ecological risk‐based management of chemicals in industrial complexes in South Korea. The system is based on a geographical information system and consists of a release rate estimation module, an exposure estimation module, and an ecological risk assessment module. For release rate and exposure estimation, the chemical use data from the national chemical inventory database and a dynamic multimedia fate model, respectively, were used. The ecological risk was assessed by calculating the risk quotient. A case study was presented to demonstrate an application of KORECORisk to setting a risk‐based priority among the 6 major industrial complexes or among the chemicals used in the individual industrial complexes. Furthermore, a more detailed assessment was performed to demonstrate and evaluate a potential use of KORECORisk for the management of individual complexes. With 3 phthalates (1,2‐benzenedicarboxylic acid dibutyl ester; 1,2‐benzenedicarboxylic acid dimethyl ester; and 1,2‐dibenzenedicarboxylic acid dioctyl ester) as model chemicals, KORECORisk provided prediction in time and space that are of sufficient resolution required for the aquatic risk assessment but with varying uncertainty. The uncertainty associated with the use of KORECORisk appeared to vary widely (from <10 to 10 3 ) with the chemical. Within the range of the chemicals tested, the release rate estimation appeared to introduce larger uncertainty than the exposure estimation. A more accurate chemical use inventory would improve the accuracy of not only the chemical release estimation but the exposure estimation module by reducing the influence of the unidentified sources. The release estimation module should be modified to provide temporal variation with a time resolution relevant to the exposure duration for which toxic effects could occur.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here