z-logo
open-access-imgOpen Access
Badania porównawcze liniowych ładunków kumulacyjnych
Author(s) -
Ł. Habera,
Instytut Nafty i Gazu – Państwowy Instytut Badawczy,
Kamil Hebda
Publication year - 2021
Publication title -
nafta gaz
Language(s) - English
Resource type - Journals
ISSN - 0867-8871
DOI - 10.18668/ng.2021.06.02
Subject(s) - enclosure , materials science , shaped charge , structural engineering , borehole , casting , voltage , composite material , engineering , geotechnical engineering , explosive material , electrical engineering , chemistry , organic chemistry
The fireground tests are the best method for verifying the operation effectiveness of the entire shooting device or its component parts in real conditions. The purpose of the fireground tests presented herein was the physical verification of linear shaped charge (LSC) ability to perforate multi-layered target, reflecting the material and geometrical conditions of a borehole. The series of shooting tests included tests of three types of linear shaped charges selected for use in perfo-fracturing devices. The following shaped charges were tested: LSC in lead enclosure, having φ = 40 mm circular cross-section with shaped recess; LSC with copper liner in 20/30 mm steel trapezoid enclosure; LSC with liner made of solid copper, in 20/40 mm steel trapezoidal enclosure.During testing, the cumulative jet velocity was recorded using voltage type probes, arranged between the individual layers of a target composed of steel and concrete materials. The research method adapted for the project purposes was aimed at verification of the following thesis: whether the proposed shaped charges fulfil the technical and performance conditions for their effective application in the oil industry. The criterion adopted was the ability – or lack of ability – to perforate the multi-layered barrier in the form of two steel plates and concrete casting. The testing stand, single-use by its nature, was each time composed of concrete block having 400 mm ´ 250 mm ´ 150 mm dimensions and 20 MPa static compressive strength, on which two steel plates were placed parallel to each other with 20 mm spacing. The thickness of the plates was 5 mm and 10 mm respectively. The tested shaped charge was placed on the top steel plate at a distance of one calibre – that is the distance equal to the opening of the trapezoidal shaped charge and full diameter of circular cross-section charge. Furthermore, within media interface planes (steel/air, air/steel; steel/concrete), the set of voltage-type measuring probes was installed, in the form of single electric wires (φ = 0.25 mm). At an instant when they break (circuit break) as a result of cumulative jet operation, voltage drop in the subsequent measuring probes will act as a logical gate of start-stop type, or in other words the zero-one (0–1) type gate. The readings of individual probes breakage times allowed in addition to determine the velocity of the cumulative jet and to estimate its braking dynamics while passing through the subsequent elements of multi-layered target.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here