z-logo
open-access-imgOpen Access
SPECTROPHOTOMETRIC DETERMINATION OF COPPER (II) AFTER DISPERSIVE LIQUID-LIQUID EXTRACTION OF ITS COMPLEX WITH 6,7-DIHYDROXY-4-METHYL-2-PHENYLBENZOPYRYLIUM CHLORIDE
Author(s) -
Denys Snigur
Publication year - 2021
Publication title -
vìsnik odesʹkogo nacìonalʹnogo unìversitetu. hìmìâ
Language(s) - English
Resource type - Journals
eISSN - 2414-5963
pISSN - 2304-0947
DOI - 10.18524/2304-0947.2021.4(80).248296
Subject(s) - chloroform , copper , chloride , extraction (chemistry) , detection limit , chemistry , liquid–liquid extraction , liquid liquid , calibration curve , chromatography , solvent , dispersion (optics) , spectrophotometry , analytical chemistry (journal) , organic chemistry , physics , optics
The specificity of the dispersive liquid-liquid semi-microextraction of Copper (II) complex with 6,7-dihydroxy-4-methyl-2-phenylbenzopyryl chloride has been studied. It is noted that the transition to semi-microextraction technology can significantly reduce the toxic organic solvents consumption, and the use of dispersion solvent can intensify the complex extraction of Сopper (II) complex with 6,7-dihydroxy-4-methyl-2-phenylbenzopyryl chloride. Optimal conditions for spectrophotometric determination of Сopper (II) after dispersive liquid-liquid semi-microextraction of its complex with 6,7-dihydroxy-4-methyl-2-phenylbenzopyrylium chloride were found to be: 1.5 mL of chloroform, 1.5 mL of methanol, pH 4.5, λmax = 535 nm, l = 1 cm. The main analytical characteristics of the developed dispersive liquid-liquid semi-microextraction-spectrophotometric method are calculated: the calibration graph is linear in the wide range of concentrations of 17-480 μg/L, and the limit of detection and limit of determination are 5 and 17 μg/L, respectively. The molar ratios Copper (II) : interferer, in which there is no effect on the quantitative determination of Copper(II) by the proposed dispersive liquid-liquid semi-microextraction-spectrophotometric method have been established. The proposed method for Copper (II) spectrophotometric quantification after preconcentration via dispersive liquid-liquid semi-microextraction as a complex with 6,7-dihydroxy-4-methyl-2-phenylbenzopyrilium chloride was tested in the analysis of model solutions and water samples. The accuracy of the developed dispersive liquid-liquid semi-microextraction-spectrophotometric method was checked by the "spiked-found" method and the relative standard deviation does not exceed 3.9%. The proposed technique is simple, sensitive and environmentally friendly.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here