z-logo
open-access-imgOpen Access
Polymerization Shrinkage of Five Bulk-Fill Composite Resins in Comparison with a Conventional Composite Resin
Author(s) -
Mahdi Abbasi,
Zohreh Moradi,
Mehran Mirzaei,
Mohammad Javad Kharazifard,
Samaneh Rezaei
Publication year - 2019
Publication title -
journal of dentistry
Language(s) - English
Resource type - Journals
eISSN - 2008-2185
pISSN - 1735-2150
DOI - 10.18502/jdt.v15i6.330
Subject(s) - shrinkage , polymerization , materials science , composite material , composite number , linear variable differential transformer , dental composite , polymer , transformer , physics , distribution transformer , quantum mechanics , voltage
Objectives: The polymerization shrinkage of methacrylate-based composites is among the most important causes of failure of composite restorations. The manufacturers claim that bulk-fill composites have a lower polymerization shrinkage than conventional composites. This study aimed to assess the polymerization shrinkage of five bulk-fill composites in comparison with a conventional composite. Materials and Methods: In this in-vitro experimental study, composite discs (n=30) were fabricated using everX Posterior (EXP), Filtek Bulk-Fill Posterior (FBP), SonicFill 2 (SF2), Tetric N-Ceram Bulk-Fill (TNB), X-tra fil (XF), and Filtek Z250 conventional composite at the center of a metal ring bonded to a microscope slide and were covered with a coverslip. This assembly was transferred to a linear variable differential transformer (LVDT). Light-curing (1200 mW/cm2) was performed from underneath the slide for 30 seconds. The deflecting disc method and LVDT were used to assess the dimensional changes of the samples (indicative of polymerization shrinkage) at 1, 30, 60, and 1800 seconds following the onset of light irradiation. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey’s test. Results: The groups were significantly different regarding polymerization shrinkage (P<0.002). The polymerization shrinkage of the tested composites following the onset of light irradiation ranged from 0.19 to 3.03. EXP showed a significantly higher polymerization shrinkage than other composites at 30, 60, and 1800 seconds after light irradiation, while XF showed the lowest polymerization shrinkage at the aforementioned time points. Conclusions: The tested bulk-fill composites had a polymerization shrinkage similar to that of the conventional composite.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here