Thermographic diagnostics of instability of endoprostheses of large joints with assessment of somatosympathetic vasomotor reflex
Author(s) -
А. И. Крупаткин,
А. В. Балберкин,
A. L. Baranetsky
Publication year - 2022
Publication title -
n n priorov journal of traumatology and orthopedics
Language(s) - English
Resource type - Journals
eISSN - 2658-6738
pISSN - 0869-8678
DOI - 10.17816/vto99991
Subject(s) - medicine , vasomotor , reflex , prosthesis , implant , spinal cord , surgery , joint (building) , radiology , anesthesia , architectural engineering , psychiatry , engineering
Forty two patients with total hip (12 patients) and total knee (30 patients) replacements were examined by computer thermography method. Total joint replacement was performed after bone tumor resection. It was shown that additional afferent impulsation occured at implant loosening and the degree of vertical polysegmental irradiation of sympathic neurons excitation as well as the deficit of spinal cord inhibition on the side of arthroplasty incresed. Thermographic evaluation of the amplitute and volume of somatosympathic vasomotor reflex is an effective for the diagnosis of joint prosthesis loosening and it is subsidiary to the radiologic control.