The Nature of the Force Factor between the Opposing Magnets of the Separator with Blade-type Rods
Author(s) -
В. А. Ершова,
B N Nyunin,
A. A. Sandulyak,
А. В. Сандуляк,
M N Pugacheva
Publication year - 2007
Publication title -
izvestiâ mgtu "mami"
Language(s) - English
Resource type - Journals
eISSN - 2949-1428
pISSN - 2074-0530
DOI - 10.17816/2074-0530-69666
Subject(s) - magnet , mechanics , rod , separator (oil production) , materials science , structural engineering , physics , mechanical engineering , engineering , thermodynamics , medicine , alternative medicine , pathology
On the basis of measurements of magnetic induction in a modular unit consisting of two opposing magnets it was shown that, firstly, the induction field reaches its minimum value in the middle of the block, and, secondly, with decreasing magnitude of the clearance the overall level of the field increases. On the basis of the variation found by the gradient induction and force factor it was shown that their tail sections (approximately 23-27% of the clearance) is taping off, but the induction of these tailings areas become almost self-similar, which indicates the presence of a failure zone between the opposing magnets module. As a result of ferromixtures analysis as the hazard of power facilities, the dependence for assessing of financial equivalent of risk reduction was found.