z-logo
open-access-imgOpen Access
Application of D-STATCOM for Harmonic Reduction using Power Balance Theory
Author(s) -
Rishi Kumar Singh Mohd. Navaid Ansari
Publication year - 2021
Publication title -
türk bilgisayar ve matematik eğitimi dergisi
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.218
H-Index - 3
ISSN - 1309-4653
DOI - 10.17762/turcomat.v12i6.5694
Subject(s) - harmonics , pulverizer , power factor , switched mode power supply , transformer , electrical engineering , single phase electric power , three phase , total harmonic distortion , engineering , voltage , electronic engineering , mechanical engineering , grinding
In modern power systems due to prolific use of non-linear devices harmonics are present in the distribution system. To reduce the harmonics and source neutral current D-FACT along with a star-delta transformer and Power Filter is proposed in shunt. In this article, the three phase load has been taken from NTS Industries, which deals with FMCG products. This system includes 3 phase 3 wire system having industrial load such as mixer grinder, pulverizer, packaging machine, etc. A star-delta transformer along with three leg voltage source inverter and a capacitor used to filter out harmonics present in supply current. Power balance theory is used to control the D-FACT. A MATLAB Simulink model was created and the results were discussed.