z-logo
open-access-imgOpen Access
In vitro fluoride release from a different kind of conventional and resin modified glass-ionomer cements
Author(s) -
Mediha Selimović-Dragaš,
Lajla Hasić-Branković,
Fehim Korać,
Nermin Đapo,
Amina Huseinbegović,
Sedin Kobašlija,
Meliha Lekić,
Šahza Hatibović-Kofman
Publication year - 2013
Publication title -
bosnian journal of basic medical sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.738
H-Index - 25
eISSN - 1840-4812
pISSN - 1512-8601
DOI - 10.17305/bjbms.2013.2362
Subject(s) - glass ionomer cement , fluoride , nuclear chemistry , dentistry , materials science , medicine , inorganic chemistry , chemistry
Fluoride release is important characteristic of glass-ionomer cements. Quantity of fluoride ions released from the glass-ionomer cements has major importance in definition of their biological activity. The objectives of this study were to define the quantity of fluoride ions released from the experimental glass-ionomer cements and to define the effect of fluoride ions released from the experimental glass-ionomer cements on their cytotoxicity. Concentrations of the fluoride ions released in the evaluated glass-ionomer cements were measured indirectly, by the fluoride-selective WTW, F500 electrode potential, combined with reference R503/D electrode. Statistical analyses of F-ion concentrations released by all glass-ionomers evaluated at two time points, after 8 and after 24 hours, show statistically higher fluoride releases from RMGICs: Vitrebond, Fuji II LC and Fuji Plus, when compared to conventional glass-ionomer cements: Fuji Triage, Fuji IX GP Fast and Ketac Silver, both after 8 and after 24 hours. Correlation coefficient between concentrations of fluoride ion released by evaluated glass-ionomer cements and cytotoxic response of UMR-106 osteoblast cell-line are relatively high, but do not reach levels of biological significance. Correlation between concentrations of fluoride ion released and cytotoxic response of NIH3T3 mouse fibroblast cell line after 8 hours is high, positive and statistically significant for conventional GICs, Fuji Triage and Fuji IX GP Fast, and RMGIC, Fuji II LC. Statistically significant Correlation coefficient between concentrations of fluoride ion released and cytotoxic response of NIH3T3 cell line after 24 hours is defined for RMGIC Fuji II LC only.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here