z-logo
open-access-imgOpen Access
ELECTRIC SUPPLY OF UNDERGROUND CONSUMERS OF DEEP ENERGY-INTENSIVE MINES
Author(s) -
Ф. П. Шкрабец
Publication year - 2018
Publication title -
gornye nauki i tehnologii
Language(s) - English
Resource type - Journals
ISSN - 2500-0632
DOI - 10.17073/2500-0632-2017-3-25-42
Subject(s) - voltage , reliability (semiconductor) , electricity , power (physics) , low voltage , automotive engineering , high voltage , electric potential energy , electric power , electrical engineering , engineering , reliability engineering , physics , quantum mechanics
The increase in the capacity of cleaning and construction vehicles for highcapacity and energy-intensive mines calls for an increase in the  supply voltage of cleaning and tunneling combines, as well as  transport systems: from a voltage of 660 V switched to 1140 V, and  now to 3300 V. This allows improving technical and economic  indicators for clearing and access areas, as well as improving the reliability of local Power Supply Systems (PSS). However, this  trend prevents the supply of underground electric networks with a  voltage of 6 kV, in connection with which the problem arises of  increasing the voltage of supply networks. To date, it has become  possible to apply the 10 kV voltage to the operation, which is most  acceptable for the use of electrical equipment for electrical networks  and protection devices. Leading educational, research and design  organizations were engaged in research on this issue. An analysis of the results of the research showed that switching to 10 kV voltage is  justified and timely. At the same time, 35 kV voltage is not removed  from the agenda, which is technically feasible and economically  justified, but there are problems with the safety of its operation in  underground workings, which requires appropriate refinement. This  level of voltage will improve the quality of electricity.Conclusions: 1. Application of 35 kV voltage in the underground power supply system of coal and ore mines is advisable at a depth of more than 1000 m with a maximum load of at least 1000 kVA at the  level of the stem cables.2. Application of 35 kV voltage in underground electrical networks will allow to significantly improve the quality indicators of voltage,  reliability, and economy of the system due to the current unloading  of the most important element of SES, such as stem cables.3. Analysis of the main parameters and characteristics of electrical mine electrical equipment gives reason to believe that it allows  implementing a trend of 35 kV deep input to deep horizons of mines  (mines) and placement of 35/6 kV substations on working horizons.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here