z-logo
open-access-imgOpen Access
Cardioplegia retrógrada atrial: estudo clínico
Author(s) -
Mauro Paes Leme,
A.P Jazbik,
Henrique Murad,
Eduardo Sérgio Bastos,
João Brito,
R. Giambroni,
João Carlos Moreno de Azevedo,
Leoncio Feitosa
Publication year - 1997
Publication title -
brazilian journal of cardiovascular surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.324
H-Index - 26
eISSN - 1678-9741
pISSN - 0102-7638
DOI - 10.1590/s0102-76381997000200011
Subject(s) - medicine , cardiology , aorta , anesthesia
Os autores apresentam uma série de 15 pacientes submetidos a cirurgia cardíaca cuja proteção miocárdica foi obtida por infusão de solução cardioplégica sangüínea isotérmica por via retrógrada atrial. As operações consistiram em 11 revascularizações do miocárdio e 4 cirurgias orovalvares. Após instalação da circulação extracorpórea, iniciou-se a infusão da solução cardioplégica de indução na porção inicial da aorta, exceto nos casos de insuficiência aórtica. A solução de indução foi infundida por cinco minutos, passando-se, então, à solução de manutenção. No início da infusão da solução de manutenção, através de cateter de 4,0 mm no átrio direito, as veias cavas e o tronco pulmonar foram pinçados e passou-se a aspirar a aorta. Todos os pacientes saíram de circulação extracorpórea sem qualquer dificuldade ou suporte inotrópico. Não houve registro de infarto agudo do miocárdio. Dois pacientes com fibrilação atrial apresentaram ritmo sinusal já no centro cirúrgico. This study presents the results in a group of fifteen patients submitted to cardiac surgery, using continuous atrial retrograde warm blood cardioplegia for myocardial protection. Eleven patients were submitted to myocardial revascularization and four were submitted to valvular transplantation. There was no need for inotropic drugs or intraaortic balloon pump support during or after the procedure, and no myocardial infarction was detected in this group. When the heart was arrested, the cardioplegia line was switched to the atrial cannula. The aortic root was vented throughout the cross-clamp period, and retrograde perfusion was assured by noting the engorged exygenated cardiac veins as well as the return of dark blood through the vent in the aortic root. The patients presented good clinical and laboratory course. No right ventricular dysfunction was detected. Two patients were in atrial fibrillation before the surgery, one of them returned to this cardiac rhythm three days after the procedure

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here