First experience of transcatheter implantation of a Russian-made MedLab-CT prosthesis in a patient with dysfunction of biological mitral valve prosthesis
Author(s) -
А. В. БогачевПрокофьев,
Ravil Sharifulin,
М. А. Овчаров,
Alexey Pivkin,
О. В. Крестьянинов,
Т. В. Антропова,
М. А. Овчинникова,
Д. А. Астапов,
Andrey Sapegin,
А. В. Афанасьев,
Sergei A. Budagaev,
С. И. Железнев
Publication year - 2020
Publication title -
rossijskij kardiologičeskij žurnal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.141
H-Index - 14
eISSN - 2618-7620
pISSN - 1560-4071
DOI - 10.15829/1560-4071-2020-3847
Subject(s) - medicine , prosthesis , implant , cardiology , mitral valve replacement , heart valve , stent , mitral valve , surgery , prosthesis implantation
We present a case report of successful transcatheter implantation of a Russian-made cardiac valve prosthesis in a patient with dysfunction of biological mitral valve prosthesis (valve-in-valve). A patient aged 78 years with a high surgical risk and severe heart failure due to mitral valve bioprosthesis dysfunction is described. Fluoroscopyand transesophageal echocardiography-guided transapical implantation of a MedLab-CT prosthesis (23 mm) was made. When a heart rate of 180 beats per minute, a stent prosthesis was implanted. Transcatheter implant valve functioned properly after surgery. The patient was discharged in satisfactory condition.