Novel SPECT Technologies and Approaches in Cardiac Imaging
Author(s) -
Piotr J. Slomka,
Guang-Uei Hung,
Guido Germano,
Daniel S. Berman
Publication year - 2016
Publication title -
cardiovascular innovations and applications
Language(s) - English
Resource type - Journals
eISSN - 2009-8782
pISSN - 2009-8618
DOI - 10.15212/cvia.2016.0052
Subject(s) - spect imaging , cardiac imaging , computer science , medical physics , medicine , nuclear medicine
Recent novel approaches in myocardial perfusion single photon emission CT (SPECT) have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv) stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.