
Ultrafast Computation of Left Ventricular Ejection Fraction by Using Temporal Intensity Variation in Cine Cardiac Magnetic Resonance
Author(s) -
Amol Pednekar,
Benjamin Cheong,
Raja Muthupillai
Publication year - 2021
Publication title -
texas heart institute journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.373
H-Index - 53
eISSN - 1526-6702
pISSN - 0730-2347
DOI - 10.14503/thij-20-7238
Subject(s) - steady state free precession imaging , ejection fraction , medicine , magnetic resonance imaging , cardiac magnetic resonance imaging , algorithm , intensity (physics) , stroke volume , computation , cardiac imaging , nuclear medicine , nuclear magnetic resonance , cardiology , physics , computer science , radiology , heart failure , optics
Cardiac magnetic resonance enables comprehensive cardiac evaluation; however, intense time and labor requirements for data acquisition and processing have discouraged many clinicians from using it. We have developed an alternative image-processing algorithm that requires minimal user interaction: an ultrafast algorithm that computes left ventricular ejection fraction (LVEF) by using temporal intensity variation in cine balanced steady-state free precession (bSSFP) short-axis images, with or without contrast medium. We evaluated the algorithm's performance against an expert observer's analysis for segmenting the LV cavity in 65 study participants (LVEF range, 12%-70%). In 12 instances, contrast medium was administered before cine imaging. Bland-Altman analysis revealed quantitative effects of LV basal, midcavity, and apical morphologic variation on the algorithm's accuracy. Total computation time for the LV stack was <2.5 seconds. The algorithm accurately delineated endocardial boundaries in 1,132 of 1,216 slices (93%). When contours in the extreme basal and apical slices were not adequate, they were replaced with manually drawn contours. The Bland-Altman mean differences were <1.2 mL (0.8%) for end-diastolic volume, <5 mL (6%) for end-systolic volume, and <3% for LVEF. Standard deviation of the difference was ≤4.1% of LV volume for all sections except the midcavity in end-systole (8.3% of end-systolic volume). We conclude that temporal intensity variation-based ultrafast LVEF computation is clinically accurate across a range of LV shapes and wall motions and is suitable for postcontrast cine SSFP imaging. Our algorithm enables real-time processing of cine bSSFP images on a commercial scanner console within 3 seconds in an unobtrusive automated process.