Transcatheter Tricuspid Valve-in-Valve Replacement with an Edwards Sapien 3 Valve
Author(s) -
Pranav Loyalka,
Angelo Nascimbene,
B. Metz,
Igor D. Gregorič,
Ajay Sundara Raman,
Biswajit Kar
Publication year - 2017
Publication title -
texas heart institute journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.373
H-Index - 53
eISSN - 1526-6702
pISSN - 0730-2347
DOI - 10.14503/thij-15-5639
Subject(s) - medicine , tricuspid valve , valve replacement , cardiology , heart valve , surgery , stenosis
A few case reports and case series have documented the outcomes in patients with tricuspid bioprosthetic valvular degeneration who underwent transcatheter implantation of the Medtronic Melody and the Edwards Sapien XT and Sapien 3 valves. In this report, we describe the case of a 49-year-old woman with severe bioprosthetic tricuspid valvular stenosis and multiple comorbidities who underwent transcatheter tricuspid valve replacement with a Sapien 3 valve.