Subject(s) - hormone , endocrinology , medicine , chemistry , rat model , correlation coefficient , serum concentration , chromatography , mathematics , statistics
The relationship between the matrix effect and radioimmunoassayed concentrations of total T4 in the blood of rats was studied. T4 was measured 4 times in 59 rats: by the initial and modified RIO-T4-PG and RIA-T4-STkits (Minsk). The modification consisted in the following: standard solutions were prepared on rat serum free from T4. The levels of T4 measured by the original and modified kits correlated. For RIO-T4-PG the correlation coefficient p = 0.9809 and regression equation is у = 0.64x+5.087, and for RIA-T4-ST p = 0.9802 and у = 0.875x-l. 712. Hence, for real concentrations, measurements of T4 by both original kits give underrated values, but the fluctuations of T4 in the control rats appreciably surpassed this underrating. We conclude that the above mentioned commercial kits for measuring T4 can be usedfor measuring the hormone concentration in the rat blood, provided the appropriate reference groups are available.