z-logo
open-access-imgOpen Access
Combination of Xpert® MTB/RIF and DetermineTM TB-LAM Ag improves the diagnosis of extrapulmonary tuberculosis at Jimma University Medical Center, Oromia, Ethiopia
Author(s) -
Asnake Simieneh,
Mulualem Tadesse,
Wakjira Kebede,
Mulatu Gashaw,
Gemeda Abebe
Publication year - 2022
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0263172
Subject(s) - medicine , extrapulmonary tuberculosis , tuberculosis , mycobacterium tuberculosis , gastroenterology , pathology
Background Ethiopia is one of the high burden countries for extrapulmonary tuberculosis (EPTB); however, the prompt diagnosis of EPTB remains challenging. This study is aimed to evaluate the diagnostic performance of Xpert MTB/RIF and Determine TM TB-LAM Ag (TB-LAM) for the prompt diagnosis of EPTB in Ethiopia. Methods A total of 147 presumptive EPTB patients, including 23 HIV- positive participants were enrolled. Extra-pulmonary samples were collected from all presumptive EPTB cases and tested for Mycobacterium tuberculosis complex (MTBC) using fluorescent microscopy, Xpert MTB/RIF, and culture. Additionally, urine samples were also collected from 126 participants and were tested by Determine TM TB-LAM Ag (Alere Inc, Waltham, USA). The Sensitivity and specificity of Xpert and TB- LAM tests were calculated by comparing with a composite reference standard (CRS), which comprises smear microscopy, culture and response to empirical anti-TB treatment. Results Of 147 patients, 23 (15.6%) were confirmed EPTB cases (culture-positive), 14 (9.5%) were probable EPTB (clinically, radiologically or cytologically positive and received anti-TB treatment with good response), and 110 (74.8%) were classified as “non- TB” cases. Compared to the composite reference standard (CRS), the overall sensitivity and specificity of Xpert MTB/RIF were 43.2% and 100%, respectively with the highest sensitivity for Lymph node aspirate (85.7%) and lower sensitivity for pleural fluid (14.3%) and 100% specificity for all specimen types. The sensitivity and specificity of TB-LAM were 33.3% and 94.4% respectively with the highest sensitivity for HIV co-infected participants (83.3%). The sensitivity of the combination of Xpert MTB/RIF and TB-LAM tests regardless of HIV status was 61.1% whereas the sensitivity was improved to 83.3% for HIV-positive cases. Conclusion TB-LAM alone has low sensitivity for EPTB diagnosis; however, the combination of TB-LAM and Xpert MTB/RIF improves the diagnosis of EPTB particularly for countries with high EPTB and HIV cases.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here