
Combination of Xpert® MTB/RIF and DetermineTM TB-LAM Ag improves the diagnosis of extrapulmonary tuberculosis at Jimma University Medical Center, Oromia, Ethiopia
Author(s) -
Asnake Simieneh,
Mulualem Tadesse,
Wakjira Kebede,
Mulatu Gashaw,
Gemeda Abebe
Publication year - 2022
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0263172
Subject(s) - medicine , extrapulmonary tuberculosis , tuberculosis , mycobacterium tuberculosis , gastroenterology , pathology
Background Ethiopia is one of the high burden countries for extrapulmonary tuberculosis (EPTB); however, the prompt diagnosis of EPTB remains challenging. This study is aimed to evaluate the diagnostic performance of Xpert MTB/RIF and Determine TM TB-LAM Ag (TB-LAM) for the prompt diagnosis of EPTB in Ethiopia. Methods A total of 147 presumptive EPTB patients, including 23 HIV- positive participants were enrolled. Extra-pulmonary samples were collected from all presumptive EPTB cases and tested for Mycobacterium tuberculosis complex (MTBC) using fluorescent microscopy, Xpert MTB/RIF, and culture. Additionally, urine samples were also collected from 126 participants and were tested by Determine TM TB-LAM Ag (Alere Inc, Waltham, USA). The Sensitivity and specificity of Xpert and TB- LAM tests were calculated by comparing with a composite reference standard (CRS), which comprises smear microscopy, culture and response to empirical anti-TB treatment. Results Of 147 patients, 23 (15.6%) were confirmed EPTB cases (culture-positive), 14 (9.5%) were probable EPTB (clinically, radiologically or cytologically positive and received anti-TB treatment with good response), and 110 (74.8%) were classified as “non- TB” cases. Compared to the composite reference standard (CRS), the overall sensitivity and specificity of Xpert MTB/RIF were 43.2% and 100%, respectively with the highest sensitivity for Lymph node aspirate (85.7%) and lower sensitivity for pleural fluid (14.3%) and 100% specificity for all specimen types. The sensitivity and specificity of TB-LAM were 33.3% and 94.4% respectively with the highest sensitivity for HIV co-infected participants (83.3%). The sensitivity of the combination of Xpert MTB/RIF and TB-LAM tests regardless of HIV status was 61.1% whereas the sensitivity was improved to 83.3% for HIV-positive cases. Conclusion TB-LAM alone has low sensitivity for EPTB diagnosis; however, the combination of TB-LAM and Xpert MTB/RIF improves the diagnosis of EPTB particularly for countries with high EPTB and HIV cases.