z-logo
open-access-imgOpen Access
The evaluation of the utility of the GENECUBE HQ SARS-CoV-2 for anterior nasal samples and saliva samples with a new rapid examination protocol
Author(s) -
Asami Naito,
Yoshihiko Kiyasu,
Yusaku Akashi,
Akio Sugiyama,
Masashi Michibuchi,
Yuto Takeuchi,
Shigeyuki Notake,
Koji Nakamura,
Hiroichi Ishikawa,
Hiromichi Suzuki
Publication year - 2021
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0262159
Subject(s) - saliva , concordance , medicine , polymerase chain reaction , covid-19 , respiratory system , real time polymerase chain reaction , biology , pathology , gene , biochemistry , disease , infectious disease (medical specialty)
GENECUBE ® is a rapid molecular identification system, and previous studies demonstrated that GENECUBE ® HQ SARS-CoV-2 showed excellent analytical performance for the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) with nasopharyngeal samples. However, other respiratory samples have not been evaluated. Methods This prospective comparison between GENECUBE ® HQ SARS-CoV-2 and reference real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for the detection of SARS-CoV-2 using anterior nasal samples and saliva samples. Additionally, we evaluated a new rapid examination protocol using GENECUBE ® HQ SARS-CoV-2 for the detection of SARS-CoV-2 with saliva samples. For the rapid protocol, in the preparation of saliva samples, purification and extraction processes were adjusted, and the total process time was shortened to approximately 35 minutes. Results For 359 anterior nasal samples, the total-, positive-, and negative concordance of the two assays was 99.7% (358/359), 98.1% (51/52), and 100% (307/307), respectively. For saliva samples, the total-, positive-, and negative concordance of the two assays was 99.6% (239/240), 100% (56/56), and 99.5% (183/184), respectively. With the new protocol, total-, positive-, and negative concordance of the two assays was 98.8% (237/240), 100% (56/56), and 98.4% (181/184), respectively. In all discordance cases, SARS-CoV-2 was detected by additional molecular examinations. Conclusion GENECUBE ® HQ SARS-CoV-2 provided high analytical performance for the detection of SARS-CoV-2 in anterior nasal samples and saliva samples.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here