z-logo
open-access-imgOpen Access
Differences in the gray-to-white matter ratio according to different computed tomography scanners for outcome prediction in post-cardiac arrest patients receiving target temperature management
Author(s) -
Jae Hun Oh,
Seung Pill Choi,
Jong Ho Zhu,
Soo Hyun Kim,
Kyu Nam Park,
Chun Song Youn,
Sang Hoon Oh,
Han Joon Kim,
Sang Hyun Park
Publication year - 2021
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0258480
Subject(s) - hounsfield scale , medicine , internal capsule , white matter , corpus callosum , targeted temperature management , computed tomography , receiver operating characteristic , radiology , nuclear medicine , surgery , magnetic resonance imaging , pathology , resuscitation , cardiopulmonary resuscitation , return of spontaneous circulation
The gray-to-white matter ratio (GWR) has been used to identify brain damage in comatose patients after cardiac arrest. However, Hounsfield units (HUs), the measurement of brain density on computed tomography (CT) images, may vary depending on the machine type or parameter. Therefore, differences in CT scanners may affect the GWR in post-cardiac arrest patients. We performed a retrospective study on comatose post-cardiac arrest patients who visited the hospital from 2007 to 2017. Two CT, Lightspeed and SOMATOM, scanners were used. Two observers independently measured the HUs of the caudate nucleus, putamen, posterior internal capsule, and corpus callosum using regions of interest. We compared the GWR calculated from the HUs measured at different CT scanners. The analysis of different scanners showed statistically significant differences in the measured HUs and GWR. The HUs and GWR of Lightspeed were measured lower than SOMATOM. The difference between the two CT scanners was also evident in groups divided by neurological prognosis. The area under the curve of the receiver operating characteristic curve to predict poor outcomes of Lightspeed was 0.798, and the cut-off value for 100% specificity was 1.172. The SOMATOM was 0.855, and the cut-off value was 1.269. The difference in scanners affects measurements and performance characteristics of the GWR in post-cardiac arrest patients. Therefore, when applying the results of the GWR study to clinical practice, reference values for each device should be presented, and an integrated plan should be prepared.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here