
SARS-CoV-2 antibody immunoassays in serial samples reveal earlier seroconversion in acutely ill COVID-19 patients developing ARDS
Author(s) -
Marie-Luise Buchholtz,
Florian M Arend,
Peter Eichhorn,
Michael Weigand,
Alisa Kleinhempel,
Kurt Häusler,
Mathias Bruegel,
Lesca M. Holdt,
Daniel Teupser
Publication year - 2021
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0251587
Subject(s) - seroconversion , ards , medicine , covid-19 , antibody , cohort , immunology , serology , virology , gastroenterology , lung , disease , infectious disease (medical specialty)
Objectives During the COVID-19 pandemic, SARS-CoV-2 antibody testing has been suggested for (1) screening populations for disease prevalence, (2) diagnostics, and (3) guiding therapeutic applications. Here, we conducted a detailed clinical evaluation of four Anti-SARS-CoV-2 immunoassays in samples from acutely ill COVID-19 patients and in two negative cohorts. Methods 443 serum specimens from serial sampling of 29 COVID-19 patients were used to determine clinical sensitivities. Patients were stratified for the presence of acute respiratory distress syndrome (ARDS). Individual serum specimens from a pre-COVID-19 cohort of 238 healthy subjects and from a PCR-negative clinical cohort of 257 patients were used to determine clinical specificities. All samples were measured side-by-side with the Anti-SARS-CoV-2-ELISA (IgG), Anti-SARS-CoV-2-ELISA (IgA) and Anti-SARS-CoV-2-NCP-ELISA (IgG) (Euroimmun AG, Lübeck, Germany) and the Elecsys Anti-SARS-CoV-2 ECLIA (Roche Diagnostics International, Rotkreuz, Switzerland). Results Median seroconversion occurred earlier in ARDS patients (8–9 days) than in non-ARDS patients (11–17 days), except for EUR N-IgG. Rates of positivity and mean signal ratios in the ARDS group were significantly higher than in the non-ARDS group. Sensitivities between the four tested immunoassays were equivalent. In the set of negative samples, the specificity of the Anti-SARS-CoV-2-ELISA (IgA) was lower (93.9%) compared to all other assays (≥98.8%) and the specificity of Anti-SARS-CoV-2-NCP-ELISA (IgG) was lower (98.8%) than that of Elecsys Anti-SARS-CoV-2 (100%). Conclusions Serial sampling in COVID-19 patients revealed earlier seroconversion and higher signal ratios of SARS-CoV-2 antibodies as a potential risk marker for the development of ARDS, suggesting a utility for antibody testing in acutely diseased patients.