Data-driven CAD-CAM vs traditional total contact custom insoles: A novel quantitative-statistical framework for the evaluation of insoles offloading performance in diabetic foot
Author(s) -
Moreno D’Amico,
Edyta Kinel,
Piero Roncoletta,
Andrea Gnaldi,
Celeste Ceppitelli,
Federico Belli,
Giuseppe Murdolo,
Cristiana Vermigli
Publication year - 2021
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0247915
Subject(s) - cad , diabetic foot , medicine , foot pressure , biomedical engineering , diabetes mellitus , computer science , pressure sensor , engineering drawing , engineering , mechanical engineering , endocrinology
Background Elevated plantar pressures represent a significant risk factor for neuropathic diabetic foot (NDF) ulceration. Foot offloading, through custom-made insoles, is essential for prevention and healing of NDF ulcerations. Objective quantitative evaluation to design custom-made insoles is not a standard method. Aims: 1) to develop a novel quantitative-statistical framework (QSF) for the evaluation and design of the insoles’ offloading performance through in-shoe pressure measurement; 2) to compare the pressure-relieving efficiency of traditional shape-based total contact customised insoles (TCCI) with a novel CAD-CAM approach by the QSF. Methods We recruited 30 neuropathic diabetic patients in cross-sectional study design. The risk-regions of interest (R-ROIs) and their areas with in-shoe peak pressure statistically ≥200kPa were identified for each patients’ foot as determined on the average of peak pressure maps ascertained per each stance phase. Repeated measures Friedman test compared R-ROIs’ areas in three different walking condition: flat insole (FI); TCCI and CAD-CAM insoles. Results As compared with FI (20.6±12.9 cm 2 ), both the TCCI (7±8.7 cm 2 ) and the CAD-CAM (5.5±7.3 cm 2 ) approaches provided a reduction of R-ROIs mean areas (p<0.0001). The CAD-CAM approach performed better than the TCCI with a mean pressure reduction of 37.3 kPa (15.6%) vs FI. Conclusions The CAD-CAM strategy achieves better offloading performance than the traditional shape-only based approach. The introduced QSF provides a more rigorous method to the direct 200kPa cut-off approach outlined in the literature. It provides a statistically sound methodology to evaluate the offloading insoles design and subsequent monitoring steps. QSF allows the analysis of the whole foot’s plantar surface, independently from a predetermined anatomical identification/masking. QSF can provide a detailed description about how and where custom-made insole redistributes the underfoot pressure respect to the FI. Thus, its usefulness extends to the design step, helping to guide the modifications necessary to achieve optimal offloading insole performances.