z-logo
open-access-imgOpen Access
A novel xenonucleic acid-mediated molecular clamping technology for early colorectal cancer screening
Author(s) -
Qing Sun,
Larry Pastor,
Jiang Du,
Michael J. Powell,
Aiguo Zhang,
Walter F. Bodmer,
Jianzhong Wu,
Shu Zheng,
Michael Y. Sha
Publication year - 2021
Publication title -
plos one
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.99
H-Index - 332
ISSN - 1932-6203
DOI - 10.1371/journal.pone.0244332
Subject(s) - kras , colorectal cancer , medicine , assay sensitivity , cancer , area under the curve , microbiology and biotechnology , oncology , biology , pathology , alternative medicine
Background Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape TM assay for early colorectal cancer diagnostics. Methods Nineteen mutations in four genes (APC, KRAS, BRAF and CTNNB1) associated with early events in CRC pathogenesis are targeted in the ColoScape TM assay. Xenonucleic Acid (XNA)-mediated qPCR clamping technology was applied to minimize the wild-type background amplification in order to improve assay sensitivity of CRC mutation detection. The assay analytical performance was verified and validated, cfDNA and FFPE CRC patient samples were evaluated, and an ROC curve was applied to evaluate its performance. Results The data showed that the assay analytical sensitivity was 0.5% Variant Allele Frequency, corresponding to ~7–8 copies of mutant DNA with 5 ng total DNA input per test. This assay is highly reproducible with intra-assay CV of <3% and inter-assay CV of <5%. We have investigated 380 clinical samples including plasma cfDNA and FFPE samples from patients with precancerous and different stages of CRC. The preliminary assay clinical specificity and sensitivity for CRC cfDNA were: 100% (95% CI, 80.3–97.5%) and 92.2% (95% CI, 94.7–100%), respectively, with AUC of 0.96; 96% specificity (95% CI, 77.6–99.7%) and 92% sensitivity (95% CI, 86.1–95.6%) with AUC of 0.94 for CRC FFPE; 95% specificity (95% CI, 82.5%–99.1%) and 62.5% sensitivity (95% CI, 35.8%–83.7%) with AUC of 0.79 for precancerous lesions cfDNA. Conclusions The XNA-mediated molecular clamping assay is a rapid, precise, and sensitive assay for the detection of precancerous lesions cfDNA and CRC cfDNA or FFPE samples.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here